OLYMPUS

Main Menu starts

Biliary and Pancreatic Plastic Stents

Biliary and Pancreatic Plastic Stents

Contents start

A huge variety of stents both as preloaded and single stents in many different lengths and shapes and with innovative properties offers an optimal biliary and pancreatic drainage.

  • Add to Watch List
  • Brochure

Biliary preloaded polyethylene stents - QuickPlaceV

The preloaded QuickPlace V biliary polyethylene stents are available as 8.5 and 10 Fr. in lengths from 30 to 150 mm. They come as straight, duodenal bend and center bend models and make stent placement as easy as possible.

Biliary preloaded DoubleLayer stents - QuickPlaceV

The preloaded biliary DoubleLayer stents are available as 10 Fr. duodenal bend models from 50 to 150 mm stent length. The stents feature a unique double-layer construction to optimize performance: The inner layer is made of a special material that is five times smoother than conventional plastic stents. The outer layer provides stiffness and elasticity for smooth passage through a stricture.

Biliary single polyethylene stents

The biliary polyethylene stents offer the right combination of flexibility and stiffness. The tapered design of the distal end facilitates insertion into the bile duct. The flaps and side holes are designed to increase reliability and reduce migration.

Stent insertion kits

The single use stent insertion kits are available as conventional and one-action stent insertion kits. The insertion kits ensure a good pushability and the easiest possible handling when used with the V-System endoscope.

QuickPlace V - Single-use biliary stent

V-System 8.5 Fr. pre-loaded polyethylene stents

  • Pre-loaded stent - ready to use
  • Radiopaque for superior visibility
  • Optimal combination of flexibility and stiffness
  • Tapered design for smooth insertion
  • Flaps and side holes prevent stent migration and increase bile flow
QuickPlace V Biliary Stent
  • Single use only
  • This device is packed sterile
  • This device is visible under fluoroscopic control
  • This device has a luer-lock connector or cleaning adaptor for flushing
  • This device is compatible with a 0,035" guidewire
  • This device allows for the instillation of contrast medium

Article
name
Article
number
Quantity Min. working
channel Ø
Working
length
Stent
size
Length
between
side flaps
Type Area
compatibility
PBD-V600R-0803 N1091230 1 3.2 mm 1725 mm 8.5 Fr. 30 mm Straight For billiary and pancreatic procedures
PBD-V602R-0805 N1094430 1 3.2 mm 1725 mm 8.5 Fr. 50 mm Centre
bend
For billiary and pancreatic procedures

V-System 10 Fr. pre-loaded polyethylene stents

  • Pre-loaded stent - ready to use
  • Radiopaque for superior visibility
  • Optimal combination of flexibility and stiffness
  • Tapered design for smooth insertion
  • Flaps and side holes prevent stent migration and increase bile flow
QuickPlace V Biliary Stent
  • Single use only
  • This device is packed sterile
  • This device is visible under fluoroscopic control
  • This device has a luer-lock connector or cleaning adaptor for flushing
  • This device is compatible with a 0,035" guidewire
  • This device allows for the instillation of contrast medium

Article
name
Article
number
Quantity Min. working
channel Ø
Working
length
Stent
size
Length
between
side flaps
Type Area
compatibility
PBD-V600R-1003 N1091830 1 3.7 mm 1725 mm 10 Fr. 30 mm Straight For billiary and pancreatic procedures
PBD-V600R-1015 N1092330 1 3.7 mm 1725 mm 10 Fr. 150 mm Straight For billiary and pancreatic procedures
PBD-V601R-1005 N1093430 1 3.7 mm 1725 mm 10 Fr. 50 mm Proximal
bend
For billiary and pancreatic procedures
PBD-V601R-1015 N1093830 1 3.7 mm 1725 mm 10 Fr. 150 mm Proximal
bend
For billiary and pancreatic procedures
PBD-V602R-1015 N1095330 1 3.7 mm 1725 mm 10 Fr. 150 mm Centre
bend
For billiary and pancreatic procedures

QuickPlace V - Single-use double layer stent

V-System 10 Fr. pre-loaded proximal bend DoubleLayer stents

  • Pre-loaded stent - ready to use
  • Ultra-smooth inner surface minimises cohesion and bile accumulation
  • Special outer layer for easy insertion
  • Increased patency
  • Proximal bend
QuickPlace V Double Layer
  • Single use only
  • This device is packed sterile
  • This device is visible under fluoroscopic control
  • This device has a luer-lock connector or cleaning adaptor for flushing
  • This device is compatible with a 0,035" guidewire
  • This device allows for the instillation of contrast medium

Article
name
Article
number
Quantity Min. working
channel ø
Working
length
Stent
size
Length
between
side flaps
Area
compatibility
PBD-V621R-1005 N1095430 1 3.7 mm 1725 mm 10 Fr. 50 mm For billiary and pancreatic procedures
PBD-V621R-1007 N1095530 1 3.7 mm 1725 mm 10 Fr. 70 mm For billiary and pancreatic procedures
PBD-V621R-1009 N1095630 1 3.7 mm 1725 mm 10 Fr. 90 mm For billiary and pancreatic procedures
PBD-V621R-1012 N1095730 1 3.7 mm 1725 mm 10 Fr. 120 mm For billiary and pancreatic procedures
PBD-V621R-1015 N1095830 1 3.7 mm 1725 mm 10 Fr. 150 mm For billiary and pancreatic procedures

Contents end

Top of this page
Copyright OLYMPUS CORPORATION All Rights Reserved.